FOC transmitter / decoder set - SSI, HTL/TTL (up to 1 MHz)

 
 
FOC transmitter / decoder set - SSI, HTL/TTL (up to 1 MHz) FO-TX-4 / FO-DX-4zoom

Short info: Accessories

  • Module set (transmitter FO-TX-4 + decoder FO-DX-4) for absolute values (SSI) and incremental signals (HTL or TTL)
  • Extremely fast and highly precise FOC signal transmission up to 1000 m
  • Designed for highly dynamic control of drives, including motor commutation
  • Just one fiber optic cable carries all data, integrated monitoring

Fiber optics transmitter / decoder set

Comprising the FOC transmitter FO-TX-4 and the FOC decoder FO-DX-4, the innovative module set operates extreme quickly, highly precise and completely interference-free. It transmits incremental signals (HTL or TTL) as well as absolute values (SSI). These high-performance FOC modules always prove their value as powerful team players when high frequencies are demanded of the SSI encoder to ensure reliable and robust drive control, for example, motor commutation in mining or steel industry applications. In combination with the SSI absolute encoders ASS(H) 40 or ASSH 60 (equipped with an additional incremental output), the FOC modules FO-TX-4 and FO-DX-4 also guarantee interference-free and fast signal transmissions in those environments up to 1000 m, even at clock frequencies >2 MHz. All data is transmitted along one fiber optic cable, whose performance is monitored continuously by means of integrated cable break and status monitoring. . 

 
 
 
1
2
3
4
 
 
Attribute Value
Product usage Implement FOC transmission path (1 FOC cable) for very fast and dynamic control processes (absolute + incremental)
Supply voltage 12-30 VDC
Signal input Transmitter FO-TX-4
Signal input (from encoder) Absolute SSI: DATA, DATAG, STATUS

Incremental: 0°, 90°, N, STATUS; each with inverted signals
Signal transmission (outputs transmitter module) Optical (to decoder): Fiber optic 62.5/125 µm or 50/125 µm with ST connectors. All data transmitted via a single fiber optic cable, Electrical (to absolute encoder): SSI clock frequency CLK, CLKG
Signal level Absolute SSI: RS 422

Incremental (configurable via DIP switches): HTL differential, HTL single-ended, RS 422, TTL single-ended
Signal output Decoder FO-DX-4 Signal output (to controller): Absolute SSI: DATA, DATAG, STATUS, STATUSG

Incremental: 0°, 90°, N, STATUS; each with inverted signals

Signal transmission (inputs decoder module): Optical (from transmitter): Fiber optic 62.5/125 µm or 50/125 µm with ST connectors. All data transmitted via a single fiber optic cable

Electrical (from controller): SSI clock frequency CLK, CLKG
Signal level Absolute SSI: RS 422

Incremental (selectable via a variety of module types); HTL differential (FO-DX-4 H), TTL, RS 422 (FO-DX-4 T)
Frequency range: Transmitter FO-TX-4 Incremental: Up to 1 MHz for RS 422; 400 kHz (HTL, TTL)

Absolute SSI (transmitter as master for SSI absolute encoder), preset ex works (adjustments on request): 3.67 MHz (CLK frequency), Timeout 2 µs, Resolution 13 bit (12-30 bit)
Frequency range: Decoder FO-DX-4 2 MHz (CLK frequency), Timeout 20 µs, Resolution 13 bit (adjustments on request: 12-30 bit)
Dimensions FO-TX-4 / FO-DX-4: 25 x 122 x 117 mm
Casing FO-TX-4 / FO-DX-4: Electronic housing for standard mounting rails
Device temperature range -20 °C to +70 °C
Degree of protection FO-TX-4 / FO-DX-4 (for switchboard): IP20
Electrical connection FO-TX-4 / FO-DX-4: Terminal strips and FOC connector to outside of module
Device options Constant signal processing time <1 µs (transmitter input to decoder output)

Very high sampling rate; incremental signal jitter <15 ns

Very high SSI clock frequencies >2 MHz in combination with SSI absolute encoders ASS(H) 40/60

Integrated cable break and status monitoring

FOC range up to 1000 m

Flohr Industrietechnik GmbH - Im Unteren Tal 1 - D-79761 Waldshut-Tiengen - Phone: +49 (0)7751 / 8731-0 - info@flohr-industrietechnik.de

Privacy policy

Our web site uses external components. These help us to constantly improve our offer and to provide you with a comfortable visit. By loading external components, data about your behavior may be collected by third parties, which is why we need your permission. Without your permission, there may be restrictions on content and operation. You can find detailed information in our Privacy policy.