UO-EPB / UO-SPB

 
 

Communication module PROFIBUS

 
 
U-ONE Generation II (LWL) - communication module PROFIBUSzoom

Short info: Universal encoder systems

  • UO-SPB-1: Communicates safe position and speed to a safety controller via PROFIsafe protocol
  • UO-EPB-1: Communicates position and speed to a non-safety controller via PROFIBUS-DP
  • Resolution up to 13 bit singleturn / 15 bit multiturn
  • Options: Without SIL/PL certification (UO-EPB-1); it is possible to combine 2 bus modules within a system

U-ONE Generation II (LWL) - communication module PROFIBUS

The communication modules of the U-ONE(-SAFETY) second generation transmit the position, speed and status data of the shafts that need to be monitored to a higher-level controller. They feature a PROFIBUS-DP interface. In the UO-SPB safety design (certified up to SIL 2 / PL d), the programmable parameters reference the counting direction, the idleness tolerance, the preset value, the integration time and the size of the monitoring window. In the UO-EPB standard design, the counting direction, resolution and limit switches can be parameterized.

 
 
 
Attribute Value
Supply voltage Power supplied via controller module
Signal outputs/Interfaces PROFIBUS-DP | UO-EPB

PROFIsafe via PROFIBUS-DP | UO-SPB

Resolution:

UO-EPB: 12 bit singleturn / 15 bit multiturn

UO-SPB: 13 bit singleturn / 15 bit multiturn

Bus addressing with rotary coding switch

Configurable functions:

UO-EPB: Counting direction, resolution, limit switches

UO-SPB: Counting direction, standstill tolerance, preset, integration time safe/unsafe, size of monitoring window

LED indicators: Operating conditions/warning
Electrical connection UO-EPB: D-SUB 9 connector (1x)

UO-SPB: M12 connector (1x)

Internal bus connection to preceding and following modules
Dimensions UO-EPB: 100 x 25 x 110 mm (modular electronics housing for DIN rail bus connector)

UO-SPB: 100 x 60 x 110 mm (modular electronics housing for DIN rail bus connector)
Device temperature range -25 °C to +60 °C
Degree of protection IP20 (switchboard installation)
Device options Combines with other modules belonging to the U-ONE(-SAFETY)-LWL-System

Combine of 2 bus modules possible within one system (UO-EPN/SPN/EPB/SPB)
Special features and certificates USL(H) 42 and associated modules UO-S…: SIL 2 (DIN EN 61508); PL d (DIN EN ISO 13849)

Flohr Industrietechnik GmbH - Im Unteren Tal 1 - 79761 Waldshut-Tiengen (Allemagne) - Téléphone : +49 (0)7751 / 8731-0 - info@flohr-industrietechnik.

Table des matiéres   Contact   Conditions générales de vente   Mentions légales

Politique de confidentialité   Politique de confidentialité courriel

Suivez-nous sur : Facebook | Instagram | LinkedIn  

Privacy policy

Our web site uses external components. These help us to constantly improve our offer and to provide you with a comfortable visit. By loading external components, data about your behavior may be collected by third parties, which is why we need your permission. Without your permission, there may be restrictions on content and operation. You can find detailed information in our Privacy policy.